Humeral Neck Locking Compression Locking Plate

Humeral Neck Locking Compression Locking Plate

Humeral Neck Locking Compression Locking Plate

 Thickness:1-120mm
 Width:1500-3600mm
 Length:as custom's request
 Technique:Cold rolled or hot rolled
 Surface treatment:Bare/Shot Blasted and Spray Paint or as required.
 Standard:ASTM,EN,GB,JIS,DIN

[PDF]

Zimmer® Periarticular Proximal Humeral Locking Plate ...

2 Zimmer Periarticular Proximal Humeral Locking Plate Introduction The Zimmer Periarticular Locking Plate System combines locking screw technology with periarticular plates to create fixed-angle constructs for use in comminuted fractures or where deficient

The use of locking plates in proximal humeral fractures ...

ncbi.nlm.nih.gov› …› v.3(4); Oct-Dec 2009The plate is precontoured for the proximal humerus, and the insertion of locking screws obviates the need for a plate-to-bone compression, preserving the blood supply to the bones.

Locking Plate for Proximal Humeral Fracture in the Elderly ...

ncbi.nlm.nih.gov› …› Clin Orthop Surg› v.4(3); 2012 SepThe plate is precontoured for the proximal humerus, and the insertion of locking screws obviates the need for a plate-to-bone compression, preserving the blood supply to the bones.[PDF]

Proximal Humerus Locking Plate - University of …

Proximal Humerus Locking Plate. 1 PERI-LOC™ Upper Extremity ... Proximal Humeral Plate, division of the deltoid insertion is not always required. When distal exposure is needed, the anterior one third of ... placement of the plate. Surgical neck fracture reduction may be

Locking Plate Fixation for Proximal Humerus Fractures

Björkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 ...[PDF]

3.5 mm LCP Periarticular Proximal Humerus Plate. Part of ...

locking compression plate (LCP) system. Technique Guide. Introduction Surgical Technique Product Information Table of Contents 3.5 mm LCP Periarticular Proximal Humerus Plate 2 AO Principles 4 ... Insert a locking screw in one of the two neck holes in the head of …[PDF]

OptiLock Upper Extremity Plating System Proximal …

The System is intended for fixation of fractures, osteotomies the plate to the bone of the humeral head. • All SphereLock™ (locking and non-locking) bone screws are available in lengths of 10-44mm in increments of 2mm[PDF]

Part of the DePuy Synthes Locking Compression Plate …

Part of the DePuy Synthes Locking Compression Plate ... be reduced before inserting locking screws. Precaution: If the plate is long, the radial nerve needs to be elevated off the back of the humerus and the plate placed underneath. Otherwise, the radial nerve rarely needs to be ...

(PDF) Locking Plate Fixation for Proximal Humerus Fractures

To compare the efficacy of locking plate fixation with and without inferomedial screws in maintaining the reduction of a proximal humeral fracture. METHODS. 22 synthetic humerus models were used.

China Humeral Neck Locking Compression Locking Plate ...

Orthopedic Locking Plate, LCP Plate, Humerus Locking Plate manufacturer / supplier in China, offering Humeral Neck Locking Compression Locking Plate, Orthopedic Implant Trauma Calcaneus Bone Plates Type Iiiii, Orthopedic Implant Trauma Calcaneus Bone Plates Type III and so on.[PDF]

Management of Proximal Humeral Fractures Based on …

tion and internal fixation with conventional and locked-plate fixation, and hemiarthroplasty. In the future, locked-plate ... proximal humeral fracture involving the surgical neck, greater tuberosity, or lesser tuber-osity. (Reproduced with modification, with permission from: Nho SJ, Brophy RH, Barker JU, Cornell CN, MacGillvray JD. Innovations ...

Treatment of proximal humerus fractures with locking ...

Treatment of proximal humerus fractures with locking plates: A systematic review ... V. SavolainenInternal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand, 75 ... H.A. VallierTreatment of proximal humerus fractures.[PDF]

Zimmer Locking Plate Surgical Technique

Proximal Humeral Locking Plate Surgical Technique ... alternating locking and compression screw slots in the shaft. Locking Screw Technology The heads of the locking screws contain ... through the anatomical or surgical neck of the humerus. Recommended X-rays AP View

Outcomes for four-part proximal humerus fractures treated ...

Recently, the advent of the locking-compression plate (LCP) suggests promising results for displaced osteoporotic proximal humeral fractures.8, 9 The mechanical advantage of an LCP is that it improves fracture stability due to the fixed-angle construct, that is, the bone–plate interface creates a ‘single beam’ construct; in that there is ...

Outcomes for four-part proximal humerus fractures treated ...

Recently, the advent of the locking-compression plate (LCP) suggests promising results for displaced osteoporotic proximal humeral fractures.8, 9 The mechanical advantage of an LCP is that it improves fracture stability due to the fixed-angle construct, that is, the bone–plate interface creates a ‘single beam’ construct; in that there is ...

Humerus Locking Plate, Humerus Locking Plate ... - Alibaba

Humerus Locking Plate, Wholesale Various High Quality Humerus Locking Plate Products from Global Humerus Locking Plate Suppliers and Humerus Locking Plate Factory,Importer,Exporter at …[PDF]

Locking Plate for Proximal Humeral Fracture in the …

Keywords: Proximal humeral fracture, Neck shaft angle, Elderly population, Locking plate ment on the best treatment of these fractures, particularly in older patients.

The Augment of the Stability in Locking Compression Plate ...

Objective. The objective of this study was to compare the clinical outcomes and complications between the locking compression plate (LCP) and LCP with fibular allograft in the treatment of patients with displaced proximal humerus fracture (PHF) in elderly people. Material and Methods. Between January 2010 and December 2013, a total of 97 elderly patients with displaced PHF were treated by LCP ...

Minimally Invasive Plate Osteosynthesis Using a Helical ...

A long locking compression plate (a narrow 4.5/5.0-mm locking compression plate with 12 holes or a long PHILOS plate with 10 holes) was contoured preoperatively using a cadaveric dry humerus as a ...

Treatment of three- and four-part proximal humeral ...

Then, the proximal humeral locking plate was used to fix the head and tuberosity fragments to the shaft. For four-part fractures, fixation was supplemented by absorbable sutures that passed through the holes of locking plate.

Current concepts in locking plate fixation of proximal ...

For the arrangement of this narrative non-systematic review, an exploratory search in the MEDLINE database using the keywords “proximal humeral fracture,” “locking plate,” “classification,” and “treatment” was conducted.

The Results of Internal Fixation of Proximal Humeral ...

In this study PHILOS locking plate showed good applicability, respecting bone biologic properties because of negligible interference with blood supply of the humeral head.

Two-part surgical neck fractures of the proximal part of ...

Background: Successful internal fixation of fractures of the surgical neck of the humerus can be difficult to achieve because of osteopenia of the proximal aspect of the humerus.[PDF]

Results of Proximal Humeral Fracture Fixation with ...

Results of Proximal Humeral Fracture Fixation with Anatomical Locking Compression Plate using 6 stepwise Intraoperative Criteria in Surgical Procedures: a Retrospective Study. Figure 2: Demonstrates the C-Arm setting from the other side of the operating table, opposite to the fracture side.[PDF]

Philos plate fixation for proximal humeral fractures

The locking compression plate (Philos plate) fixation provides greater angular stability than do ... Up to neck 6 Up to top of head 8 Above head 10 Range of motion (40 points) Forward elevation ... humeral fracture, the locking plate provided better[PDF]

Proximal Humerus Fracture Fixation Plate System

Proximal Humerus Fracture Fixation Plate System. 1 ... Using the 2.5mm Drill Bit, drill a hole in the humeral neck through the center of the oblong hole in the plate. Caution: Avoid over manipulating the drill bit or using excessive force, as ... on the plate. Thread the Locking Screw Drill Guide into the desired location on the plate.

Internal fixation of proximal humeral fractures with a ...

Background Proximal humeral fractures, particularly in osteoporotic patients, remain an unsolved problem as regards the durability of the osteosynthesis. The AO/ASIF group has developed a new technique which aims to preserve the biological integrity of the humeral head and secures the reduction using multiple locking screws with angular stability (Philos), thus allowing an early mobilization.Published in: Acta Orthopaedica Scandinavica · 2004Authors: Janmagnus Bjorkenheim · Jarkko Pajarinen · Vesa SavolainenAffiliation: Helsinki University Central HospitalAbout: Fixation · Osteoporosis · Osteosynthesis · Durability · Surgery

Analysis of early failure of the locking compression plate ...

Although there has been continuous evolution in the management of fracture fixation, treatment for osteoporotic proximal humerus fractures is still challenging to trauma surgeons. The purpose of this study was to report early failure of the locking compression plate (LCP) in the treatment of ...
GET IN TOUCH

We receive enquiries in English, Español (Spanish), Русский язык (Russian), Français (French) and العربية (Arabic). Our professional team will reply to you within one business day. Please feel FREE to contact us!